Myotonic Dystrophy and Atrial Fibrillation Background Paroxysmal atrial tachyarrhythmias frequently occur in myotonic dystrophy type 1 (DM1) patients. The aim of the current study was to evaluate the atrial electromechanical-delay (AEMD) in a DM1-population with normal cardiac function and its relationship to atrial fibrillation (AF) onset. Methods and Results Fifty DM1 patients (28 male; mean age 34.2 ± 11.4 years) and 50 healthy subjects used as controls, matched for age and gender, were studied for the occurrence of atrial fibrillation during a 4-year follow-up, through 30-day external loop recorder (ELR) monitoring performed every 6 months. Intra-AEMD and inter-AEMD of both atrium were measured through tissue-Doppler echocardiography. Compared to the healthy control group, the DM1 group showed a statistically significant increase in inter-AEMD and intraleft-AEMD. Dividing the DM1-group into 2 subgroups (patients with or without AF), the inter-AEMD and intraleft-AEMD were significantly higher in the subgroup with AF compared to the subgroup without AF. A cut off value of 39.2 milliseconds for intraleft-AEMD had a sensitivity of 90% and a specificity of 90% in identifying DM1 patients with AF risk. A cut off value of 57.7 milliseconds for inter-AEMD had a sensitivity of 84.2% and a specificity of 93.5% in identifying this category of patients. Conclusion Our results showed that the echocardiographic atrial electromechanical delay indices (intraleft and inter-AEMD) were significantly increased in DM1 subjects with normal cardiac function. Intraleft and inter-AEMD represent noninvasive, inexpensive, useful and simple parameters to assess the AF risk in DM1 patients.

The role of the atrial electromechanical delay in predicting atrial fibrillation in myotonic dystrophy type 1 patients

Russo V.
;
Russo M. G.
Membro del Collaboration Group
;
Calabro P.;Politano L.;Nigro G.
Supervision
2016

Abstract

Myotonic Dystrophy and Atrial Fibrillation Background Paroxysmal atrial tachyarrhythmias frequently occur in myotonic dystrophy type 1 (DM1) patients. The aim of the current study was to evaluate the atrial electromechanical-delay (AEMD) in a DM1-population with normal cardiac function and its relationship to atrial fibrillation (AF) onset. Methods and Results Fifty DM1 patients (28 male; mean age 34.2 ± 11.4 years) and 50 healthy subjects used as controls, matched for age and gender, were studied for the occurrence of atrial fibrillation during a 4-year follow-up, through 30-day external loop recorder (ELR) monitoring performed every 6 months. Intra-AEMD and inter-AEMD of both atrium were measured through tissue-Doppler echocardiography. Compared to the healthy control group, the DM1 group showed a statistically significant increase in inter-AEMD and intraleft-AEMD. Dividing the DM1-group into 2 subgroups (patients with or without AF), the inter-AEMD and intraleft-AEMD were significantly higher in the subgroup with AF compared to the subgroup without AF. A cut off value of 39.2 milliseconds for intraleft-AEMD had a sensitivity of 90% and a specificity of 90% in identifying DM1 patients with AF risk. A cut off value of 57.7 milliseconds for inter-AEMD had a sensitivity of 84.2% and a specificity of 93.5% in identifying this category of patients. Conclusion Our results showed that the echocardiographic atrial electromechanical delay indices (intraleft and inter-AEMD) were significantly increased in DM1 subjects with normal cardiac function. Intraleft and inter-AEMD represent noninvasive, inexpensive, useful and simple parameters to assess the AF risk in DM1 patients.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/426700
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 28