BACKGROUND: Paroxysmal atrial tachyarrhythmias occur frequently in myotonic dystrophy type 1 (MD1) patients. Pacemakers, implanted for the treatment of bradyarrhythmias and including detailed diagnostic functions, may facilitate the diagnosis and management of frequent paroxysmal atrial fibrillation (AF) that may remain undetected during a conventional clinical follow-up. The effect of right ventricular pacing on AF incidence is still controversial. AIM: To evaluate the influence of a high percentage of right ventricular pacing on AF in MD1 patients during a 12-month follow-up period. METHODS: We enrolled in the present study 70 MD1 patients (age 51.3 ± 5 years; 32 females) who underwent dual chamber pacemaker implantation. At 12 months of follow-up, the study population was divided into three groups according to the percentage of atrial and ventricular stimulation: Group 1, the atrial sensing ventricular sensing group (ASVS; n = 22; age 52 ± 7.7; eight female) with a percentage of atrial and ventricular stimulation lower than 50%; Group 2, the atrial sensingventricular pacing group (ASVP; n = 24; age 50.5 ± 7.6; 13 female) with a percentage of atrial stimulation lower than 50% and percentage of ventricular stimulation higher than 80%; and Group 3, the atrial pacing ventricular pacing group (APVP; n = 24; age 56 ± 4.3; 11 female) with a percentage of atrial and ventricular stimulation higher than 80%. We counted the number of episodes of atrial arrhythmia that occurred during the observation period and the duration of each episode. RESULTS: We found a statistically significant difference in the number and duration of AF episodes between the three groups at the 12-month follow-up. In particular, there were more episodes (253 ± 30 vs. 80 ± 27 vs. 53 ± 32; p < 0.03) and longer durations of AF (8,700 ± 630 vs. 4,480 ± 975 vs. 3,853 ± 870 min; p < 0.03) in the ASVP group than in the ASVS group and the APVP group. Lead parameters remained stable over time and there were no displacements of the electrodes after implantation. CONCLUSIONS: In a 12-month follow-up comparison, we showed a statistically significant increase in paroxysmal AF episodesin MD1 patients with a high percentage of right ventricular pacing and a lower percentage of atrial stimulation.

Does a high percentage of right ventricular pacing influence the incidence of paroxysmal atrial fibrillation in myotonic dystrophy type 1 patients?

Russo V;POLITANO, Luisa;GOLINO, Paolo;RUSSO, Maria Giovanna;CALABRO', Raffaele;NIGRO, Gerardo
2013

Abstract

BACKGROUND: Paroxysmal atrial tachyarrhythmias occur frequently in myotonic dystrophy type 1 (MD1) patients. Pacemakers, implanted for the treatment of bradyarrhythmias and including detailed diagnostic functions, may facilitate the diagnosis and management of frequent paroxysmal atrial fibrillation (AF) that may remain undetected during a conventional clinical follow-up. The effect of right ventricular pacing on AF incidence is still controversial. AIM: To evaluate the influence of a high percentage of right ventricular pacing on AF in MD1 patients during a 12-month follow-up period. METHODS: We enrolled in the present study 70 MD1 patients (age 51.3 ± 5 years; 32 females) who underwent dual chamber pacemaker implantation. At 12 months of follow-up, the study population was divided into three groups according to the percentage of atrial and ventricular stimulation: Group 1, the atrial sensing ventricular sensing group (ASVS; n = 22; age 52 ± 7.7; eight female) with a percentage of atrial and ventricular stimulation lower than 50%; Group 2, the atrial sensingventricular pacing group (ASVP; n = 24; age 50.5 ± 7.6; 13 female) with a percentage of atrial stimulation lower than 50% and percentage of ventricular stimulation higher than 80%; and Group 3, the atrial pacing ventricular pacing group (APVP; n = 24; age 56 ± 4.3; 11 female) with a percentage of atrial and ventricular stimulation higher than 80%. We counted the number of episodes of atrial arrhythmia that occurred during the observation period and the duration of each episode. RESULTS: We found a statistically significant difference in the number and duration of AF episodes between the three groups at the 12-month follow-up. In particular, there were more episodes (253 ± 30 vs. 80 ± 27 vs. 53 ± 32; p < 0.03) and longer durations of AF (8,700 ± 630 vs. 4,480 ± 975 vs. 3,853 ± 870 min; p < 0.03) in the ASVP group than in the ASVS group and the APVP group. Lead parameters remained stable over time and there were no displacements of the electrodes after implantation. CONCLUSIONS: In a 12-month follow-up comparison, we showed a statistically significant increase in paroxysmal AF episodesin MD1 patients with a high percentage of right ventricular pacing and a lower percentage of atrial stimulation.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/192701
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 6
social impact