Background The subcutaneous implantable cardioverter-defibrillator (S-ICD) is recommended for patients at risk of sudden cardiac death who do not require pacing or antitachycardia pacing (ATP). However, patients with a history of monomorphic ventricular tachycardia (MVT), which is often amenable to ATP, are underrepresented in clinical studies dealing with S-ICD. Objective This study aimed to evaluate outcomes of S-ICD therapy in patients with previous MVT and describe subsequent management strategies in clinical practice. Methods From 2164 consecutive de novo S-ICD implantations, we identified 210 patients (10%) with a history of sustained MVT. Clinical characteristics, procedural data, and outcomes were analyzed. The endpoints of the study included the rates of sustained MVT and S-ICD shocks for all ventricular arrhythmias. Results During a median follow-up of 43 months (interquartile range 21-70), 21 patients (10%) experienced 66 MVT episodes (60 isolated, 6 storms) and a total of 98 ventricular arrhythmic episodes, all successfully terminated by shocks. The annualized rate of MVT was 2.8%/y, and the rate of appropriate shocks was 4.9%/y. First-shock efficacy was 93% for both MVT and polymorphic ventricular tachycardia/ventricular fibrillation. Approximately half of patients with recurrent MVT underwent ablation, with high procedural success. No patient required S-ICD explantation or conversion to a transvenous implantable cardioverter-defibrillator for ATP delivery. The complication rate was 2.3%/y and the inappropriate shock rate 2.8%/y. Conclusion In patients with previous MVT, the S-ICD provided safe and effective protection against ventricular arrhythmias. Ablation was the preferred management strategy, and no patients required conversion to a transvenous device. These findings support the use of the S-ICD as a viable option in this patient population. Clinical Trial Registration URL: http://clinicaltrials.gov/ identifier: NCT02275637.

Subcutaneous ICD therapy in patients with monomorphic ventricular tachycardia: Arrhythmia recurrence, shock rate, and management strategies

Nigro, Gerardo;
2026

Abstract

Background The subcutaneous implantable cardioverter-defibrillator (S-ICD) is recommended for patients at risk of sudden cardiac death who do not require pacing or antitachycardia pacing (ATP). However, patients with a history of monomorphic ventricular tachycardia (MVT), which is often amenable to ATP, are underrepresented in clinical studies dealing with S-ICD. Objective This study aimed to evaluate outcomes of S-ICD therapy in patients with previous MVT and describe subsequent management strategies in clinical practice. Methods From 2164 consecutive de novo S-ICD implantations, we identified 210 patients (10%) with a history of sustained MVT. Clinical characteristics, procedural data, and outcomes were analyzed. The endpoints of the study included the rates of sustained MVT and S-ICD shocks for all ventricular arrhythmias. Results During a median follow-up of 43 months (interquartile range 21-70), 21 patients (10%) experienced 66 MVT episodes (60 isolated, 6 storms) and a total of 98 ventricular arrhythmic episodes, all successfully terminated by shocks. The annualized rate of MVT was 2.8%/y, and the rate of appropriate shocks was 4.9%/y. First-shock efficacy was 93% for both MVT and polymorphic ventricular tachycardia/ventricular fibrillation. Approximately half of patients with recurrent MVT underwent ablation, with high procedural success. No patient required S-ICD explantation or conversion to a transvenous implantable cardioverter-defibrillator for ATP delivery. The complication rate was 2.3%/y and the inappropriate shock rate 2.8%/y. Conclusion In patients with previous MVT, the S-ICD provided safe and effective protection against ventricular arrhythmias. Ablation was the preferred management strategy, and no patients required conversion to a transvenous device. These findings support the use of the S-ICD as a viable option in this patient population. Clinical Trial Registration URL: http://clinicaltrials.gov/ identifier: NCT02275637.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/616785
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact