: (1) Background: In the last few years, many randomized controlled trials (RCTs) have compared direct Macintosh laryngoscopy with McGrath videolaryngoscopy in order to assess the potential benefits of the latter; the results were sometimes controversial. (2) Methods: We conducted a comprehensive literature search to identify our articles according to inclusion and exclusion criteria: to be included, each study had to be a prospective randomized trial or comparison between the McGrath videolaryngoscope and the Macintosh laryngoscope in an adult population. We did not include manikin trials or studies involving double-lumen tubes. (3) Results: 10 studies met the inclusion criteria necessary. In total, 655 patients were intubated with the McGrath and 629 with the Macintosh. In total, 1268 of 1284 patients were successfully intubated, showing equivalent results for the two devices: 648 of 655 patients with the McGrath videolaryngoscope and 620 of 629 patients with the Macintosh laryngoscope. No differences were noted in terms of hemodynamic changes or the incidence of adverse events. (4) Conclusions: We can assert that the McGrath videolaryngoscope and Macintosh laryngoscope, even if with equivalent tracheal intubation results, supplement each other.

Comparison of McGrath Videolaryngoscope versus Macintosh Laryngoscope in Tracheal Intubation: An Updated Systematic Review

Sansone, Pasquale;Giaccari, Luca Gregorio;Bonomo, Antonio;Aurilio, Caterina;Coppolino, Francesco;Passavanti, Maria Beatrice;Pota, Vincenzo;Pace, Maria Caterina
2023

Abstract

: (1) Background: In the last few years, many randomized controlled trials (RCTs) have compared direct Macintosh laryngoscopy with McGrath videolaryngoscopy in order to assess the potential benefits of the latter; the results were sometimes controversial. (2) Methods: We conducted a comprehensive literature search to identify our articles according to inclusion and exclusion criteria: to be included, each study had to be a prospective randomized trial or comparison between the McGrath videolaryngoscope and the Macintosh laryngoscope in an adult population. We did not include manikin trials or studies involving double-lumen tubes. (3) Results: 10 studies met the inclusion criteria necessary. In total, 655 patients were intubated with the McGrath and 629 with the Macintosh. In total, 1268 of 1284 patients were successfully intubated, showing equivalent results for the two devices: 648 of 655 patients with the McGrath videolaryngoscope and 620 of 629 patients with the Macintosh laryngoscope. No differences were noted in terms of hemodynamic changes or the incidence of adverse events. (4) Conclusions: We can assert that the McGrath videolaryngoscope and Macintosh laryngoscope, even if with equivalent tracheal intubation results, supplement each other.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/516128
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact