: In recent years, a significant improvement in left ventricular assist device (LVAD) technology has occurred, and the continuous-flow devices currently used can last more than 10 years in a patient. Current studies report that the 5-year survival rate after LVAD implantation approaches that after a heart transplant. However, the outcome is influenced by the correct selection of the patients, as well as the choice of the optimal time for implantation. This review summarizes the indications, the red flags for prompt initiation of LVAD evaluation, and the principles for appropriate patient screening.

In recent years, a significant improvement in left ventricular assist device (LVAD) technology has occurred, and the continuous-flow devices currently used can last more than 10 years in a patient. Current studies report that the 5-year survival rate after LVAD implantation approaches that after a heart transplant. However, the outcome is influenced by the correct selection of the patients, as well as the choice of the optimal time for implantation. This review summarizes the indications, the red flags for prompt initiation of LVAD evaluation, and the principles for appropriate patient screening.

How to Select Patients for Left Ventricular Assist Devices? A Guide for Clinical Practice

Martucci, Maria L;Catapano, Dario;De Feo, Marisa;
2023

Abstract

In recent years, a significant improvement in left ventricular assist device (LVAD) technology has occurred, and the continuous-flow devices currently used can last more than 10 years in a patient. Current studies report that the 5-year survival rate after LVAD implantation approaches that after a heart transplant. However, the outcome is influenced by the correct selection of the patients, as well as the choice of the optimal time for implantation. This review summarizes the indications, the red flags for prompt initiation of LVAD evaluation, and the principles for appropriate patient screening.
2023
: In recent years, a significant improvement in left ventricular assist device (LVAD) technology has occurred, and the continuous-flow devices currently used can last more than 10 years in a patient. Current studies report that the 5-year survival rate after LVAD implantation approaches that after a heart transplant. However, the outcome is influenced by the correct selection of the patients, as well as the choice of the optimal time for implantation. This review summarizes the indications, the red flags for prompt initiation of LVAD evaluation, and the principles for appropriate patient screening.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/509168
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact