Background: Severe tricuspid regurgitation (TR) is known to be associated with substantial morbidity and mortality. Objectives: The authors sought to study the acute outcomes of subjects treated by tricuspid transcatheter edge-to-edge repair with the TriClip system (Abbott) in a contemporary, real-world setting. Methods: The bRIGHT (An Observational Real-World Study Evaluating Severe Tricuspid Regurgitation Patients Treated With the Abbott TriClip™ Device) postapproval study is a prospective, single-arm, open-label, multicenter, postmarket registry conducted at 26 sites in Europe. Echocardiographic assessment was performed at a core laboratory. Results: Enrolled subjects were elderly (79 ± 7 years of age) with significant comorbidities. Eighty-eight percent had baseline massive or torrential TR, and 80% of subjects were in NYHA functional class III or IV. Successful device implantation occurred in 99% of subjects, and TR was reduced to ≤moderate at 30 days in 77%. Associated significant improvements in NYHA functional class (I/II, 20% to 79%; P < 0.0001) and Kansas City Cardiomyopathy Questionnaire score (19 ± 23 points improvement; P < 0.0001) were observed at 30 days. With baseline TR grade removed as a variable, smaller right atrial volume and smaller tethering distance at baseline were independent predictors of TR reduction to ≤moderate at discharge (OR: 0.679; 95% CI: 0.537-0.858; P = 0.0012; OR: 0.722; 95% CI: 0.564-0.924; P = 0.0097). Fourteen subjects (2.5%) experienced a major adverse event at 30 days. Conclusions: Transcatheter tricuspid valve repair was found to be safe and effective in treating significant TR in a diverse, real-world population. (An Observational Real-World Study Evaluating Severe Tricuspid Regurgitation Patients Treated With the Abbott TriClip™ Device [bRIGHT]; NCT04483089)

Short-Term Outcomes of Tricuspid Edge-to-Edge Repair in Clinical Practice

Golino P.
Conceptualization
;
2023

Abstract

Background: Severe tricuspid regurgitation (TR) is known to be associated with substantial morbidity and mortality. Objectives: The authors sought to study the acute outcomes of subjects treated by tricuspid transcatheter edge-to-edge repair with the TriClip system (Abbott) in a contemporary, real-world setting. Methods: The bRIGHT (An Observational Real-World Study Evaluating Severe Tricuspid Regurgitation Patients Treated With the Abbott TriClip™ Device) postapproval study is a prospective, single-arm, open-label, multicenter, postmarket registry conducted at 26 sites in Europe. Echocardiographic assessment was performed at a core laboratory. Results: Enrolled subjects were elderly (79 ± 7 years of age) with significant comorbidities. Eighty-eight percent had baseline massive or torrential TR, and 80% of subjects were in NYHA functional class III or IV. Successful device implantation occurred in 99% of subjects, and TR was reduced to ≤moderate at 30 days in 77%. Associated significant improvements in NYHA functional class (I/II, 20% to 79%; P < 0.0001) and Kansas City Cardiomyopathy Questionnaire score (19 ± 23 points improvement; P < 0.0001) were observed at 30 days. With baseline TR grade removed as a variable, smaller right atrial volume and smaller tethering distance at baseline were independent predictors of TR reduction to ≤moderate at discharge (OR: 0.679; 95% CI: 0.537-0.858; P = 0.0012; OR: 0.722; 95% CI: 0.564-0.924; P = 0.0097). Fourteen subjects (2.5%) experienced a major adverse event at 30 days. Conclusions: Transcatheter tricuspid valve repair was found to be safe and effective in treating significant TR in a diverse, real-world population. (An Observational Real-World Study Evaluating Severe Tricuspid Regurgitation Patients Treated With the Abbott TriClip™ Device [bRIGHT]; NCT04483089)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/505389
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 15
social impact