Implantable intramedullary nail lengthening devices (e.g., PRECICE 2 system) have been proposed as alternative method to external fixation for lower limb lengthening surgery. The aim of this study was to analyse our outcomes and complications using the PRECICE 2 (P2) nail system and review them in light of the existing literature. A retrospective multicentre study was conducted on patients <18 years, who were treated for limb lengthening using the P2 system. The inclusion criteria were a limb length discrepancy >= 30 mm and a follow-up >= 6 months after the end of treatment. A total of 26 (15 males) patients were included, average age was 14.7 +/- 2.3 years; 26 nails (21 femur, 5 tibia) were implanted. The average goal lengthening was 49.4 +/- 12.4 mm, while average achieved lengthening was 44.4 +/- 11.6 mm. Average distraction and consolidation indexes were 11.9 +/- 2.1 days/cm and 25.1 +/- 8.1 days/cm, respectively. Nail accuracy and reliability were 91.1% and 88.5%, respectively. A total of five problems (joint contractures), one obstacle (femur fracture) and three complications (hip joint subluxation, deep infection and nail running back) were encountered. The P2 nail system is a valid alternative to external fixator for limb lengthening in young patients with no significant angular or rotation deformities. Our study confirms a favourable complication rate and available evidence from literature suggests a lower complication rate than external fixator systems. Nevertheless, surgeons should keep a watchful eye on risk of joint subluxation and mechanical complications with intramedullary lengthening.

Clinical results and complication rates of lower limb lengthening in paediatric patients using the PRECICE 2 intramedullary magnetic nail: a multicentre study

Nasto, Luigi Aurelio;
2020

Abstract

Implantable intramedullary nail lengthening devices (e.g., PRECICE 2 system) have been proposed as alternative method to external fixation for lower limb lengthening surgery. The aim of this study was to analyse our outcomes and complications using the PRECICE 2 (P2) nail system and review them in light of the existing literature. A retrospective multicentre study was conducted on patients <18 years, who were treated for limb lengthening using the P2 system. The inclusion criteria were a limb length discrepancy >= 30 mm and a follow-up >= 6 months after the end of treatment. A total of 26 (15 males) patients were included, average age was 14.7 +/- 2.3 years; 26 nails (21 femur, 5 tibia) were implanted. The average goal lengthening was 49.4 +/- 12.4 mm, while average achieved lengthening was 44.4 +/- 11.6 mm. Average distraction and consolidation indexes were 11.9 +/- 2.1 days/cm and 25.1 +/- 8.1 days/cm, respectively. Nail accuracy and reliability were 91.1% and 88.5%, respectively. A total of five problems (joint contractures), one obstacle (femur fracture) and three complications (hip joint subluxation, deep infection and nail running back) were encountered. The P2 nail system is a valid alternative to external fixator for limb lengthening in young patients with no significant angular or rotation deformities. Our study confirms a favourable complication rate and available evidence from literature suggests a lower complication rate than external fixator systems. Nevertheless, surgeons should keep a watchful eye on risk of joint subluxation and mechanical complications with intramedullary lengthening.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/484377
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 24
social impact