PURPOSE: To assess the accuracy of the following intraocular lens (IOL) power formulas: Barrett True-K No History (BTKNH), Emmetropia Verifying Optical 2.0 Post Myopic LASIK/PRK (EVO 2.0), Haigis-L, American Society of Cataract and Refractive Surgery (ASCRS) average, and Shammas, designed for patients who have undergone previous myopic refractive surgery, independent of preexisting clinical history and corneal tomographic measurements.METHODS: Data from 302 eyes of 302 patients who previously underwent myopic refractive surgery and had cataract surgery done by a single surgeon with only one IOL type inserted were included. The predicted refraction was calculated for each of the formulas and compared with the actual refractive outcome to give the prediction error. Subgroup analysis based on the axial length and mean keratometry was performed.RESULTS: On the basis of mean absolute prediction error (MAE), the formulas were ranked as follows: Haigis-L (0.61 diopters [D]), ASCRS average (0.63 D), BTKNH (0.67 D), EVO 2.0 (0.68 D), and Shammas (0.69 D). The Haigis-L had a statistically significant lower MAE compared with all formulas (P < .05) except the ASCRS average. Hyperopic mean prediction errors were seen in all formulas for axial lengths of greater than 30 mm or mean keratometry values of 35.00 diopters or less.CONCLUSIONS: The Haigis-L and the ASCRS average formulas provided the most accurate results in the overall population evaluated in this study. Moreover, according to data observed, it is important to be careful handling very long eyes and very flat corneas because hyperopic refractions could be more common.

Accuracy of Formulas for Intraocular Lens Power Calculation After Myopic Refractive Surgery

Lanza, Michele
;
Ruggiero, Adriano;Simonelli, Francesca;
2022

Abstract

PURPOSE: To assess the accuracy of the following intraocular lens (IOL) power formulas: Barrett True-K No History (BTKNH), Emmetropia Verifying Optical 2.0 Post Myopic LASIK/PRK (EVO 2.0), Haigis-L, American Society of Cataract and Refractive Surgery (ASCRS) average, and Shammas, designed for patients who have undergone previous myopic refractive surgery, independent of preexisting clinical history and corneal tomographic measurements.METHODS: Data from 302 eyes of 302 patients who previously underwent myopic refractive surgery and had cataract surgery done by a single surgeon with only one IOL type inserted were included. The predicted refraction was calculated for each of the formulas and compared with the actual refractive outcome to give the prediction error. Subgroup analysis based on the axial length and mean keratometry was performed.RESULTS: On the basis of mean absolute prediction error (MAE), the formulas were ranked as follows: Haigis-L (0.61 diopters [D]), ASCRS average (0.63 D), BTKNH (0.67 D), EVO 2.0 (0.68 D), and Shammas (0.69 D). The Haigis-L had a statistically significant lower MAE compared with all formulas (P < .05) except the ASCRS average. Hyperopic mean prediction errors were seen in all formulas for axial lengths of greater than 30 mm or mean keratometry values of 35.00 diopters or less.CONCLUSIONS: The Haigis-L and the ASCRS average formulas provided the most accurate results in the overall population evaluated in this study. Moreover, according to data observed, it is important to be careful handling very long eyes and very flat corneas because hyperopic refractions could be more common.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/484212
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 9
social impact