Data-driven Automated Fault Detection and Diagnosis (AFDD) is the automated process of detecting deviations (faults) from normal operation and diagnosing the type of problem and/or its location based on the exploitation of data collected under normal and faulty conditions. The performance of a typical single duct dual-fan constant air volume air-handling unit (AHU) are investigated through a number of experiments performed during Italian cooling and heating seasons under both fault free and faulty scenarios. The AHU operation is analysed while artificially introducing six typical faults: 1) positive offset (+3 °C) of the return air temperature sensor; 2) negative offset (-3 °C) of the return air temperature sensor; 3) positive offset (+15 %) of the return air relative humidity sensor; 4) negative offset (-15 %) of the return air relative humidity sensor; 5) complete failure of the return air fan; 6) complete failure of the supply air fan. The faulty tests are compared with the fault free experiments performed under the same boundary conditions to assess the impacts of the faults on both thermal/hygrometric indoor comfort and patterns of key operating parameters with the aim of supporting the studies focusing on new and accurate Data-driven AFDD methods for AHUs.

Experimental assessment of ground-truth faults in a typical single-duct dual-fan air-handling unit under Mediterranean climatic conditions: Impact scenarios of sensors’ offset and fans’ failure

Antonio Rosato
;
Francesco Guarino;Mohammad El Youssef;Massimiliano Masullo;Luigi Maffei
2022

Abstract

Data-driven Automated Fault Detection and Diagnosis (AFDD) is the automated process of detecting deviations (faults) from normal operation and diagnosing the type of problem and/or its location based on the exploitation of data collected under normal and faulty conditions. The performance of a typical single duct dual-fan constant air volume air-handling unit (AHU) are investigated through a number of experiments performed during Italian cooling and heating seasons under both fault free and faulty scenarios. The AHU operation is analysed while artificially introducing six typical faults: 1) positive offset (+3 °C) of the return air temperature sensor; 2) negative offset (-3 °C) of the return air temperature sensor; 3) positive offset (+15 %) of the return air relative humidity sensor; 4) negative offset (-15 %) of the return air relative humidity sensor; 5) complete failure of the return air fan; 6) complete failure of the supply air fan. The faulty tests are compared with the fault free experiments performed under the same boundary conditions to assess the impacts of the faults on both thermal/hygrometric indoor comfort and patterns of key operating parameters with the aim of supporting the studies focusing on new and accurate Data-driven AFDD methods for AHUs.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/479069
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 3
social impact