The optimal placement of a tracheal tube following percutaneous dilator tracheostomy is technically demanding in patients with tracheal stents. We report a successful technique of tracheostomy tube placement with PercuTwist in an intubated patient with a tracheal stent for malignant stenosis. The endotracheal tube was replaced with a laryngeal mask, a 9.0-mm tracheostomy tube was inserted into the trachea over a PercuTwist percutaneous dilator and through the tracheal stent under video-bronchoscopic vision. The PercuTwist technique kept the lumen of trachea, a laryngeal mask enabled adequate ventilation, and a video-bronchoscope guided the prompt insertion of the tracheostomy tube through the stent.

PercuTwist tracheostomy in an intubated patient with tracheal stent

Bove M.;Ferraro F.;Morgillo F.;Natale G.;Santini M.;Fiorelli A.
2021

Abstract

The optimal placement of a tracheal tube following percutaneous dilator tracheostomy is technically demanding in patients with tracheal stents. We report a successful technique of tracheostomy tube placement with PercuTwist in an intubated patient with a tracheal stent for malignant stenosis. The endotracheal tube was replaced with a laryngeal mask, a 9.0-mm tracheostomy tube was inserted into the trachea over a PercuTwist percutaneous dilator and through the tracheal stent under video-bronchoscopic vision. The PercuTwist technique kept the lumen of trachea, a laryngeal mask enabled adequate ventilation, and a video-bronchoscope guided the prompt insertion of the tracheostomy tube through the stent.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/463722
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact