Background: To map the choroidal vascularity index and compare two eyes in patients with unilateral central serous chorioretinopathy (CSCR). Methods: This was a retrospective, observa-tional study performed in patients with unilateral CSCR. Choroidal thickness (CT) and Choroidal vascularity index (CVI) were measured and mapped in various zones according to the early treatment diabetic retinopathy (ETDRS) grid. Results: A total of 20 CSCR patients (20 study and 20 fellow eyes) were included in the study. Outer nasal region CT was seen to be significantly lower than central CT (p = 0.042) and inner nasal CT (p = 0.007); outer ring CT was significantly less than central (p = 0.04) and inner ring (p = 0.01) CT in CSCR eyes. On potting all the CVI values against the corresponding CT values, a positive correlation was seen in CSCR eyes (r = 0.54, p < 0.01), which was slightly weaker in fellow eyes (r = 0.3, p < 0.01) and a negative correlation was seen in healthy eyes (r = −0.262, p < 0.01). Conclusions: Correlation between CVI and CT was altered in CSCR eyes as compared to fellow and normal eyes with increasing CVI towards the center of the macula and superiorly in CSCR eyes.

Choroidal vascularity map in unilateral central serous chorioretinopathy: A comparison with fellow and healthy eyes

Chandra K.;Lanza M.;Iovino C.;
2021

Abstract

Background: To map the choroidal vascularity index and compare two eyes in patients with unilateral central serous chorioretinopathy (CSCR). Methods: This was a retrospective, observa-tional study performed in patients with unilateral CSCR. Choroidal thickness (CT) and Choroidal vascularity index (CVI) were measured and mapped in various zones according to the early treatment diabetic retinopathy (ETDRS) grid. Results: A total of 20 CSCR patients (20 study and 20 fellow eyes) were included in the study. Outer nasal region CT was seen to be significantly lower than central CT (p = 0.042) and inner nasal CT (p = 0.007); outer ring CT was significantly less than central (p = 0.04) and inner ring (p = 0.01) CT in CSCR eyes. On potting all the CVI values against the corresponding CT values, a positive correlation was seen in CSCR eyes (r = 0.54, p < 0.01), which was slightly weaker in fellow eyes (r = 0.3, p < 0.01) and a negative correlation was seen in healthy eyes (r = −0.262, p < 0.01). Conclusions: Correlation between CVI and CT was altered in CSCR eyes as compared to fellow and normal eyes with increasing CVI towards the center of the macula and superiorly in CSCR eyes.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/459729
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact