Herein, we report a new technique of middle lobe fixation using Hemopatch after thoracoscopic right upper lobectomy. A 3-0 atraumatic polypropylene suture is passed first through the Hemopatch, then two not-inflated lobes, and then again patch. The lung is half-inflated, and the Hemopatch is placed onto the surface of the two half-inflated lobes in a bridging manner over the fissure. The suture is then tied by a clip. This procedure was successfully applied in five consecutive patients after thoracoscopic right upper lobectomy for cancer. No complications occurred during and after operation.

Hemopatch to Fix Mobile Lobe after Thoracoscopic Lobectomy

Fiorelli A.
;
Cascone R.;Santini M.
2020

Abstract

Herein, we report a new technique of middle lobe fixation using Hemopatch after thoracoscopic right upper lobectomy. A 3-0 atraumatic polypropylene suture is passed first through the Hemopatch, then two not-inflated lobes, and then again patch. The lung is half-inflated, and the Hemopatch is placed onto the surface of the two half-inflated lobes in a bridging manner over the fissure. The suture is then tied by a clip. This procedure was successfully applied in five consecutive patients after thoracoscopic right upper lobectomy for cancer. No complications occurred during and after operation.