In this paper, a vertical drop test of a full composite fuselage section of a regional aircraft has been presented. This test was performed to investigate the structural response of a prototype of a composite fuselage section as well as the biomechanical response of the anthropomorphic dummies under a vertical crash loading condition. The research activity, carried out within the framework of Metodi di CERtificazione e Verifica Innovativi ed Avanzati (CERVIA) project, allowed collecting suitable amount of data for the assessment of the reliability of numerical models. The test article consists of a composite fuselage section with a diameter of 3445mmand a total length of 4750mm.It includes all main structural components, the passengers, and the cargo floor structure. Fuselage section has been also equipped with an aeronautical three-seat row. The accelerations, recorded in different locations, demonstrate that the structure is able to absorb a considerable impact energy amount, thus to mitigate the acceleration levels induced to the passengers.

Vertical drop test of composite fuselage section of a regional aircraft

Riccio A.;De Luca A.;Caputo F.
Supervision
2020

Abstract

In this paper, a vertical drop test of a full composite fuselage section of a regional aircraft has been presented. This test was performed to investigate the structural response of a prototype of a composite fuselage section as well as the biomechanical response of the anthropomorphic dummies under a vertical crash loading condition. The research activity, carried out within the framework of Metodi di CERtificazione e Verifica Innovativi ed Avanzati (CERVIA) project, allowed collecting suitable amount of data for the assessment of the reliability of numerical models. The test article consists of a composite fuselage section with a diameter of 3445mmand a total length of 4750mm.It includes all main structural components, the passengers, and the cargo floor structure. Fuselage section has been also equipped with an aeronautical three-seat row. The accelerations, recorded in different locations, demonstrate that the structure is able to absorb a considerable impact energy amount, thus to mitigate the acceleration levels induced to the passengers.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/423209
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 23
social impact