Background: To evaluate sensitivity, specificity, and positive and negative predictive values (PPV and NPV, respectively) of renal ultrasonography (US) in predicting renal uptake defects or reduced renal function at Tc-99m dimercaptosuccinic acid (DMSA) scan (primary outcome). We also evaluated which factors could be associated with Tc-99m DMSA renal scan anomalies. Methods: We retrospectively included all the patients with vesico-ureteral reflux (VUR) undergoing the first Tc-99m DMSA renal scan within 3 months from the most recent renal US between 2016 and 2018. Results: Sensitivity, specificity, PPV, and NPV of US in predicting abnormal Tc-99m DMSA scan were 38.9%, 91.5%, 71.9%, and 72.9%, respectively. Different length between the kidneys, expressed as standard deviation score (SDS), showed an area under the receiver operating characteristic curve of 0.70 (95% CI, 0.60–0.80; p < 0.0001) when evaluated as predictor of abnormal Tc-99m DMSA scan. A different length between the two kidneys >1.11 SDS had 91.5% sensitivity and 57.6% specificity. At multivariate analysis, the factors with significantly increased odds ratio of abnormal Tc-99m DMSA scan were difference in length between two kidneys >1.11 SDS and dilated VUR. Conclusions: The Tc-99m DMSA scan remains the gold standard to detect renal parenchymal anomalies. A different length between the kidneys >1.11 SDS and dilated VUR are predictors of abnormal Tc-99m DMSA renal scan.

In children with urinary tract infection reduced kidney length and vesicoureteric reflux predict abnormal DMSA scan

Rambaldi P. F.;Miraglia del Giudice E.;La Manna A.;Marzuillo P.
2020

Abstract

Background: To evaluate sensitivity, specificity, and positive and negative predictive values (PPV and NPV, respectively) of renal ultrasonography (US) in predicting renal uptake defects or reduced renal function at Tc-99m dimercaptosuccinic acid (DMSA) scan (primary outcome). We also evaluated which factors could be associated with Tc-99m DMSA renal scan anomalies. Methods: We retrospectively included all the patients with vesico-ureteral reflux (VUR) undergoing the first Tc-99m DMSA renal scan within 3 months from the most recent renal US between 2016 and 2018. Results: Sensitivity, specificity, PPV, and NPV of US in predicting abnormal Tc-99m DMSA scan were 38.9%, 91.5%, 71.9%, and 72.9%, respectively. Different length between the kidneys, expressed as standard deviation score (SDS), showed an area under the receiver operating characteristic curve of 0.70 (95% CI, 0.60–0.80; p < 0.0001) when evaluated as predictor of abnormal Tc-99m DMSA scan. A different length between the two kidneys >1.11 SDS had 91.5% sensitivity and 57.6% specificity. At multivariate analysis, the factors with significantly increased odds ratio of abnormal Tc-99m DMSA scan were difference in length between two kidneys >1.11 SDS and dilated VUR. Conclusions: The Tc-99m DMSA scan remains the gold standard to detect renal parenchymal anomalies. A different length between the kidneys >1.11 SDS and dilated VUR are predictors of abnormal Tc-99m DMSA renal scan.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/421307
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 14
social impact