In this study, we investigated the effects of tDCS over the posterior parietal cortex (PPC) during a visual working memory (WM) task, which probes different sources of response error underlying the precision of WM recall. In two separate experiments, we demonstrated that tDCS enhanced WM precision when applied bilaterally over the PPC, independent of electrode configuration. In a third experiment, we demonstrated with unilateral electrode configuration over the right PPC, that only cathodal tDCS enhanced WM precision and only when baseline performance was low. Looking at the effects on underlying sources of error, we found that cathodal stimulation enhanced the probability of correct target response across all participants by reducing feature-misbinding. Only for low-baseline performers, cathodal stimulation also reduced variability of recall. We conclude that cathodal- but not anodal tDCS can improve WM precision by preventing feature-misbinding and hereby enhancing attentional selection. For low-baseline performers, cathodal tDCS also protects the memory trace. Furthermore, stimulation over bilateral PPC is more potent than unilateral cathodal tDCS in enhancing general WM precision. (C) 2016 The Authors. Published by Elsevier Ltd.
Cathodal transcranial direct current stimulation over posterior parietal cortex enhances distinct aspects of visual working memory
Sagliano L.;
2016
Abstract
In this study, we investigated the effects of tDCS over the posterior parietal cortex (PPC) during a visual working memory (WM) task, which probes different sources of response error underlying the precision of WM recall. In two separate experiments, we demonstrated that tDCS enhanced WM precision when applied bilaterally over the PPC, independent of electrode configuration. In a third experiment, we demonstrated with unilateral electrode configuration over the right PPC, that only cathodal tDCS enhanced WM precision and only when baseline performance was low. Looking at the effects on underlying sources of error, we found that cathodal stimulation enhanced the probability of correct target response across all participants by reducing feature-misbinding. Only for low-baseline performers, cathodal stimulation also reduced variability of recall. We conclude that cathodal- but not anodal tDCS can improve WM precision by preventing feature-misbinding and hereby enhancing attentional selection. For low-baseline performers, cathodal tDCS also protects the memory trace. Furthermore, stimulation over bilateral PPC is more potent than unilateral cathodal tDCS in enhancing general WM precision. (C) 2016 The Authors. Published by Elsevier Ltd.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.