The paper deals with the problem of the bearing capacity of pile groups under vertical eccentric load. Widespread practice is to consider the achievement of the axial capacity on the outermost pile as the ultimate limit state of the pile group. However, this approach neglects the ductility of the foundation system and may be thereby overconservative. With the aim of proposing an alternative and more rational approach, a novel formulation for interaction diagrams based on theorems of limit analysis is presented and discussed. The methodology is applicable to the general case of groups of unevenly distributed, dissimilar piles. Piles’ connections to the pile cap are modeled as either hinges or rigid-plastic internal fixities. An application example to a slender structure is also provided, showing that the proposed approach can lead to significant advantages over the traditional design.
Bearing capacity of pile groups under vertical eccentric load
Di Laora, Raffaele
;
2019
Abstract
The paper deals with the problem of the bearing capacity of pile groups under vertical eccentric load. Widespread practice is to consider the achievement of the axial capacity on the outermost pile as the ultimate limit state of the pile group. However, this approach neglects the ductility of the foundation system and may be thereby overconservative. With the aim of proposing an alternative and more rational approach, a novel formulation for interaction diagrams based on theorems of limit analysis is presented and discussed. The methodology is applicable to the general case of groups of unevenly distributed, dissimilar piles. Piles’ connections to the pile cap are modeled as either hinges or rigid-plastic internal fixities. An application example to a slender structure is also provided, showing that the proposed approach can lead to significant advantages over the traditional design.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.