Herein, we described a novel method as the use of AcuBlade robotic microsurgery system to manage idiopathic subglottic stenosis in a 73 years old lady. Compared to traditional CO2 lasers, AcuBlade facilitated the scar resection by the generation of different shape of beams (straight, curved, or disk). The same setting used for phonomicrosurgery (1-mm beam length, power of 10 W and pulse duration of 0.05-s) allowed to obtain fast, long, and uniform cuts. In addition, the reduction of the number of laser passes over the same area prevented injury of adjacent tissue and thus reduced the risk of recurrence. This article is protected by copyright. All rights reserved.

Herein, we described a novel method as the use of AcuBlade robotic microsurgery system to manage idiopathic subglottic stenosis in a 73-y-old lady. Compared to traditional CO2 lasers, AcuBlade facilitated the scar resection by the generation of different shape of beams (straight, curved, or disk). The same setting used for phonomicrosurgery (1-mm beam length, power of 10 W and pulse duration of 0.05-s) allowed to obtain fast, long, and uniform cuts. In addition, the reduction of the number of laser passes over the same area prevented injury of adjacent tissue and thus reduced the risk of recurrence.

Endoscopic treatment of idiopathic subglottic stenosis with digital AcuBlade robotic microsurgery system

FIORELLI, Alfonso;COSTA, Giuseppe;SANTINI, Mario
2018

Abstract

Herein, we described a novel method as the use of AcuBlade robotic microsurgery system to manage idiopathic subglottic stenosis in a 73-y-old lady. Compared to traditional CO2 lasers, AcuBlade facilitated the scar resection by the generation of different shape of beams (straight, curved, or disk). The same setting used for phonomicrosurgery (1-mm beam length, power of 10 W and pulse duration of 0.05-s) allowed to obtain fast, long, and uniform cuts. In addition, the reduction of the number of laser passes over the same area prevented injury of adjacent tissue and thus reduced the risk of recurrence.
2018
Herein, we described a novel method as the use of AcuBlade robotic microsurgery system to manage idiopathic subglottic stenosis in a 73 years old lady. Compared to traditional CO2 lasers, AcuBlade facilitated the scar resection by the generation of different shape of beams (straight, curved, or disk). The same setting used for phonomicrosurgery (1-mm beam length, power of 10 W and pulse duration of 0.05-s) allowed to obtain fast, long, and uniform cuts. In addition, the reduction of the number of laser passes over the same area prevented injury of adjacent tissue and thus reduced the risk of recurrence. This article is protected by copyright. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/352888
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact