Cardiotrophin-1 (CT-1) is a member of the interleukin (IL-6) family of cytokines. Plasma CT-1 levels correlate with the left ventricle mass index in patients with dilatated cardiomyopathy and congestive heart failure (CHF). The aim of this paper was to evaluate CT-1 plasma levels, before and after cardiac resynchronization therapy CRT, and to characterizeits prognostic role in patients with CHF. Fifty-two consecutive patients (M/F = 39/13; 56 ± 11 years old) underwent clinical and echocardiographic evaluation, and blood sample collection at baseline. The same evaluation was repeated 6.4 ± 0.79 months after CRT. Patients with a decreased LV end-systolic volume by at least 15% (reverse remodeling) were considered echo responders to CRT. Twenty-nine patients (56%) were responders to CRT. After CRT, only 15 patients (29%) showed increased CT-1 after CRT. They were all non responders to CRT. A multivariate, logistic modelshowed CT-1 as an independent predictor of CRT echo response (p = 0.005; OR 0.97). During follow-up (18 ± 7 months), 21 cardiac events in 18 patients occurred. A Cox multivariable model showed plasma BNP pre-CRT (p = 0.02; CI 1.2-5.6; OR 3.1) and CT1 post-CRT (p = 0.01; CI 1.4-4.3; OR 2.7) as independent predictors of cardiac events. Analysis of CT-1 plasma levels deserves future consideration for larger, longitudinal studies in patients with CHF.

Effect of cardiac resynchronization therapy on cardiotrophin-1 circulating levels in patients with heart failure

LIMONGELLI, Giuseppe;CALABRO', Paolo;DI SALVO, Giovanni;RUSSO, Maria Giovanna;
2014

Abstract

Cardiotrophin-1 (CT-1) is a member of the interleukin (IL-6) family of cytokines. Plasma CT-1 levels correlate with the left ventricle mass index in patients with dilatated cardiomyopathy and congestive heart failure (CHF). The aim of this paper was to evaluate CT-1 plasma levels, before and after cardiac resynchronization therapy CRT, and to characterizeits prognostic role in patients with CHF. Fifty-two consecutive patients (M/F = 39/13; 56 ± 11 years old) underwent clinical and echocardiographic evaluation, and blood sample collection at baseline. The same evaluation was repeated 6.4 ± 0.79 months after CRT. Patients with a decreased LV end-systolic volume by at least 15% (reverse remodeling) were considered echo responders to CRT. Twenty-nine patients (56%) were responders to CRT. After CRT, only 15 patients (29%) showed increased CT-1 after CRT. They were all non responders to CRT. A multivariate, logistic modelshowed CT-1 as an independent predictor of CRT echo response (p = 0.005; OR 0.97). During follow-up (18 ± 7 months), 21 cardiac events in 18 patients occurred. A Cox multivariable model showed plasma BNP pre-CRT (p = 0.02; CI 1.2-5.6; OR 3.1) and CT1 post-CRT (p = 0.01; CI 1.4-4.3; OR 2.7) as independent predictors of cardiac events. Analysis of CT-1 plasma levels deserves future consideration for larger, longitudinal studies in patients with CHF.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/217608
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact