A modified polyethersulphone graft membrane was loaded with antiproteases, with the aim of reducing the active protease blood concentration during hemodialysis in acute catabolic renal failure or cardiopulmonary bypass. As protease/antiprotease system, elastase and α 1 -antitrypsin were used. The concentration of active elastase in aqueous solutions decreased as function of contact time with the membrane, approaching saturation. A 40% loss of elastase activity was obtained at pH 7.4, which was not due to autolysis, which accounted for 5% of the loss. The highest reduction was achieved at pH 9.0 (25% higher than at pH 7.4). The saturation level of elastase decrease, calculated by means of the Einstein equation, was reached after more than 47 minutes. We speculate that a time reduction might be achieved either increasing the concentration of immobilized antiproteases, or increasing the rate of elastase movement across the membranes by hydraulic, osmotic, or temperature gradients. This technology can be applied to hemodialysis, and in extracorporeal blood circulation to promote elastase release.

The α 1 -antitrypsin/elastase complex as an experimental model for hemodialysis in acute catabolic renal failure, extracorporeal blood circulation and cardiocirculatory bypass

DIANO, Nadia;PORTACCIO, Marianna Bianca Emanuela;PERNA, Alessandra;
2002

Abstract

A modified polyethersulphone graft membrane was loaded with antiproteases, with the aim of reducing the active protease blood concentration during hemodialysis in acute catabolic renal failure or cardiopulmonary bypass. As protease/antiprotease system, elastase and α 1 -antitrypsin were used. The concentration of active elastase in aqueous solutions decreased as function of contact time with the membrane, approaching saturation. A 40% loss of elastase activity was obtained at pH 7.4, which was not due to autolysis, which accounted for 5% of the loss. The highest reduction was achieved at pH 9.0 (25% higher than at pH 7.4). The saturation level of elastase decrease, calculated by means of the Einstein equation, was reached after more than 47 minutes. We speculate that a time reduction might be achieved either increasing the concentration of immobilized antiproteases, or increasing the rate of elastase movement across the membranes by hydraulic, osmotic, or temperature gradients. This technology can be applied to hemodialysis, and in extracorporeal blood circulation to promote elastase release.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/196901
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 12
social impact