The work was devised to compare measurements of glomerular filtration rate (GFR) by technetium-99m-dietlyl-enetriaminepentacetic acid (99mTc-DTPA) renogram to those by creatinine clearance (measured and predicted by Cockroft and Gault) and by inulin clearance. A total number of 65 individuals were enrolled: 15 healthy controls and 50 patients with renal disease. Compared to inulin clearance used as the gold standard, 99mTc-DTPA overestimated at low and underestimated at high GFRs. 99mTc-DTPA measurements were less precise than creatinine clearance except for individuals with GFR > 100 ml/min x 1.73 m2. Measured creatinine clearance had the highest correlation coefficient with inulin clearance, 99mTc-DTPA clearance the lowest. In correlation analyses, 81.5% of the interindividual variability for measured creatinine clearance could be explained by true differences in inulin clearance; this value dropped to 59.1 and 57.4% for predicted creatinine clearance and 99mTcDTPA, respectively. In patients with GFR < 25 ml/min x 1.73 m2, all 99mTc-DTPA measurements were out of the 95% confidence interval for the inulin measurement. It can be inferred that 99mTc-DTPA clearance from the renogram is less precise than measured and predicted creatinine clearance.

Measurement of glomerular filtration rate by the 99mTc-DTPA renogram is less precise than measured and predicted creatinine clearance

ANASTASIO, Pietro;CAPASSO, Giovambattista
1999

Abstract

The work was devised to compare measurements of glomerular filtration rate (GFR) by technetium-99m-dietlyl-enetriaminepentacetic acid (99mTc-DTPA) renogram to those by creatinine clearance (measured and predicted by Cockroft and Gault) and by inulin clearance. A total number of 65 individuals were enrolled: 15 healthy controls and 50 patients with renal disease. Compared to inulin clearance used as the gold standard, 99mTc-DTPA overestimated at low and underestimated at high GFRs. 99mTc-DTPA measurements were less precise than creatinine clearance except for individuals with GFR > 100 ml/min x 1.73 m2. Measured creatinine clearance had the highest correlation coefficient with inulin clearance, 99mTc-DTPA clearance the lowest. In correlation analyses, 81.5% of the interindividual variability for measured creatinine clearance could be explained by true differences in inulin clearance; this value dropped to 59.1 and 57.4% for predicted creatinine clearance and 99mTcDTPA, respectively. In patients with GFR < 25 ml/min x 1.73 m2, all 99mTc-DTPA measurements were out of the 95% confidence interval for the inulin measurement. It can be inferred that 99mTc-DTPA clearance from the renogram is less precise than measured and predicted creatinine clearance.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/187931
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 41
social impact