Objectives: The aim of this study was to clinically and histologically compare two implants placed into fresh extraction sites: one immediately loaded and the other one unloaded. Methods: Two teeth in need of extraction and localized in two symmetric quadrants were selected. Baseline clinical and radiographic exams were performed. Teeth were extracted and dental implants immediately inserted into fresh extraction sites. One of them was connected with a healing abutment (control), while the other one was immediately loaded (test) by a resin crown. Clinical and radiographic examinations were performed at follow-up visits. After six months both control and test implants were removed, together with the peri-implant bone, and histologically examined. Results: Both implants appeared radiographically osseointegrated and clinically stable at retrieval time. Mineralized tissue was found at the implant interface. The bone-to-implant contact percentage in the control and test implants was 58 ± 4.0% and 52 ± 3.2%, respectively. In the loaded implant a more compact, mature, well-organized peri-implant bone was found, with many remodelling areas and some osteons, whereas the bone tissue surrounding the unloaded implant was constituted only by thin bone trabeculae. Conclusions: Immediate loading did not seem to impair osseointegration of an immediately loaded postextraction implant, compared to an unloaded postextraction one. Further studies, with a larger number of samples, are needed to confirm these preliminary results.

Immediately Loaded Postextraction Implants: A Human Histologic Case Report

GUIDA, Luigi;ANNUNZIATA, Marco;
2007

Abstract

Objectives: The aim of this study was to clinically and histologically compare two implants placed into fresh extraction sites: one immediately loaded and the other one unloaded. Methods: Two teeth in need of extraction and localized in two symmetric quadrants were selected. Baseline clinical and radiographic exams were performed. Teeth were extracted and dental implants immediately inserted into fresh extraction sites. One of them was connected with a healing abutment (control), while the other one was immediately loaded (test) by a resin crown. Clinical and radiographic examinations were performed at follow-up visits. After six months both control and test implants were removed, together with the peri-implant bone, and histologically examined. Results: Both implants appeared radiographically osseointegrated and clinically stable at retrieval time. Mineralized tissue was found at the implant interface. The bone-to-implant contact percentage in the control and test implants was 58 ± 4.0% and 52 ± 3.2%, respectively. In the loaded implant a more compact, mature, well-organized peri-implant bone was found, with many remodelling areas and some osteons, whereas the bone tissue surrounding the unloaded implant was constituted only by thin bone trabeculae. Conclusions: Immediate loading did not seem to impair osseointegration of an immediately loaded postextraction implant, compared to an unloaded postextraction one. Further studies, with a larger number of samples, are needed to confirm these preliminary results.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/164937
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact