The dynamic increase factor for nonlinear static alternate path analysis of steel frames against progressive collapse initiated by column loss was investigated. The influence of the fundamental parameters involved in progressive collapse analysis was highlighted. The effect of number of stories, number of bays, location of the removed column and level of seismic design load was in-vestigated. The dynamic increase factor was estimated in a way to generate the best match of the peak dynamic responses through the nonlinear static analysis. The values obtained were finally expressed as a function of the vertical displacement at the location of the removed column and compared with the GSA formulation based on the ductility factor.

É stato valutato il fattore di amplificazione dinamica da adottare nell’analisi statica non lineare di telai in acciaio soggetti al collasso progressivo indotto della perdita di una colonna. È stata evi-denziata l’influenza dei diversi parametri coinvolti nell’analisi a collasso progressivo. È stato va-lutato, in particolare, l’effetto del numero di piani, del numero di campate, della posizione della colonna rimossa e del livello di progetto. Il fattore di amplificazione dinamico è stato calibrato mediante il confronto tra i valori di picco dell’analisi dinamica non lineare ed i risultati dell’analisi statica non lineare. I valori ottenuti, espressi in funzione dello spostamento verticale nella posizione della colonna rimossa, sono stati infine confrontati con la formulazione proposta dalle Linee Guida GSA basata sulla duttilità disponibile.

Assessment of dynamic increase factors for progressive collapse analysis of steel frames subjected to column failure

Massimiliano Ferraioli;Alberto Mandara
2017

Abstract

The dynamic increase factor for nonlinear static alternate path analysis of steel frames against progressive collapse initiated by column loss was investigated. The influence of the fundamental parameters involved in progressive collapse analysis was highlighted. The effect of number of stories, number of bays, location of the removed column and level of seismic design load was in-vestigated. The dynamic increase factor was estimated in a way to generate the best match of the peak dynamic responses through the nonlinear static analysis. The values obtained were finally expressed as a function of the vertical displacement at the location of the removed column and compared with the GSA formulation based on the ductility factor.
2017
978-88-8552-200-8
É stato valutato il fattore di amplificazione dinamica da adottare nell’analisi statica non lineare di telai in acciaio soggetti al collasso progressivo indotto della perdita di una colonna. È stata evi-denziata l’influenza dei diversi parametri coinvolti nell’analisi a collasso progressivo. È stato va-lutato, in particolare, l’effetto del numero di piani, del numero di campate, della posizione della colonna rimossa e del livello di progetto. Il fattore di amplificazione dinamico è stato calibrato mediante il confronto tra i valori di picco dell’analisi dinamica non lineare ed i risultati dell’analisi statica non lineare. I valori ottenuti, espressi in funzione dello spostamento verticale nella posizione della colonna rimossa, sono stati infine confrontati con la formulazione proposta dalle Linee Guida GSA basata sulla duttilità disponibile.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/380600
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 12
social impact