A set-up for the measurement of the frequency response of voltage measurement transformers under actual waveform conditions is presented. It is based on the two steps procedure that makes use of high voltage gas insulated capacitors and a digital bridge. It allows for calibration using distorted waveforms, with a fundamental tone at medium voltage level and a harmonic content up to 10% and 10 kHz. A practical application to a frequency calibration of a voltage measurement transformer is also presented.

Frequency calibration of MV voltage transformer under actual waveforms

GALLO, Daniele;LANDI, Carmine;LUISO, Mario;
2016

Abstract

A set-up for the measurement of the frequency response of voltage measurement transformers under actual waveform conditions is presented. It is based on the two steps procedure that makes use of high voltage gas insulated capacitors and a digital bridge. It allows for calibration using distorted waveforms, with a fundamental tone at medium voltage level and a harmonic content up to 10% and 10 kHz. A practical application to a frequency calibration of a voltage measurement transformer is also presented.
2016
9781467391344
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/376544
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 0
social impact