In this study the progressive collapse-resisting capacities of steel moment-resisting frame buildings designed according to the Italian Code were evaluated. At first, a stepwise increment of amplified vertical loads (pushdown analysis) for a variety of possible scenarios regarding the location of the missing column was employed. Then, as the nonlinear dynamic analysis for progressive collapse analysis does not require modelling of complicated hysteretic behaviour and may be used as a practical tool, it was applied for evaluation of progressive collapse potential with the same first story column suddenly removed. According to the analysis results, the progressive collapse potential varied significantly depending on the location of the removed column. It was also observed that the pushdown analysis may greatly overestimate the inelastic response of the structure. É stata proposta una variante adattiva del metodo dello spettro di capacità e degli spettri inelastici. La procedura migliora l’efficace nella stima della risposta sismica, ed essendo non iterativa, evita i problemi connessi alla non convergenza o alla presenza di soluzioni multiple. L’accuratezza dell’analisi statica è stata verificata mediante il confronto con l’analisi dinamica non lineare al passo condotta su telai in acciaio con controventi ad instabilità impediti soggetti ad input sismico. I risultati sono stati infine confrontati con quelli ottenuti applicando le procedure proposte dalle FEMA440-ATC-55 basate sul Metodo dello Spettro di Capacità ovvero sul Metodo dei Coefficienti di spostamento.

Progressive collapse analysis of steel frame buildings

FERRAIOLI, Massimiliano;MANDARA, Alberto
2011

Abstract

In this study the progressive collapse-resisting capacities of steel moment-resisting frame buildings designed according to the Italian Code were evaluated. At first, a stepwise increment of amplified vertical loads (pushdown analysis) for a variety of possible scenarios regarding the location of the missing column was employed. Then, as the nonlinear dynamic analysis for progressive collapse analysis does not require modelling of complicated hysteretic behaviour and may be used as a practical tool, it was applied for evaluation of progressive collapse potential with the same first story column suddenly removed. According to the analysis results, the progressive collapse potential varied significantly depending on the location of the removed column. It was also observed that the pushdown analysis may greatly overestimate the inelastic response of the structure. É stata proposta una variante adattiva del metodo dello spettro di capacità e degli spettri inelastici. La procedura migliora l’efficace nella stima della risposta sismica, ed essendo non iterativa, evita i problemi connessi alla non convergenza o alla presenza di soluzioni multiple. L’accuratezza dell’analisi statica è stata verificata mediante il confronto con l’analisi dinamica non lineare al passo condotta su telai in acciaio con controventi ad instabilità impediti soggetti ad input sismico. I risultati sono stati infine confrontati con quelli ottenuti applicando le procedure proposte dalle FEMA440-ATC-55 basate sul Metodo dello Spettro di Capacità ovvero sul Metodo dei Coefficienti di spostamento.
2011
978-88-89972-23-6
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/321803
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact