BACKGROUND: Axillary lymphadenectomy remains an integral part of breast cancer treatment, yet seroma formation occurs in 15-85% of cases. Among methods to reduce seroma magnitude and duration, fibrin glue has been proposed in several studies with controversial results. PATIENTS AND METHODS: Ninety patients underwent quadrantectomy or mastectomy with level I/II axillary lymphadenectomy; a suction drain was fitted in all patients. Fibrin glue spray were applied to the axillary fossa in 45 patients; the other 45 patients were treated conventionally. RESULTS: Suction drainage was removed between post-operative (p.o.) days 3 and 4. Seroma magnitude and duration were significantly reduced (p 0.004 and 0.02, respectively), and there were fewer evacuative punctures, in patients receiving fibrin glue compared with the conventional treatment group. CONCLUSIONS: Use of fibrin glue does not always prevent seroma formation, but does reduce seroma magnitude, duration and evacuative punctures.

NEW TRENDS ON FIBRIN GLUE IN SEROMA AFTER AXILLARY LYMPHADENECTOMY FOR BREAST CANCER

RUGGIERO, Roberto;PROCACCINI, Eugenio;PARMEGGIANI, Domenico;CONZO, Giovanni;DOCIMO, Ludovico;GUBITOSI, Adelmo;DOCIMO, Giovanni;
2009

Abstract

BACKGROUND: Axillary lymphadenectomy remains an integral part of breast cancer treatment, yet seroma formation occurs in 15-85% of cases. Among methods to reduce seroma magnitude and duration, fibrin glue has been proposed in several studies with controversial results. PATIENTS AND METHODS: Ninety patients underwent quadrantectomy or mastectomy with level I/II axillary lymphadenectomy; a suction drain was fitted in all patients. Fibrin glue spray were applied to the axillary fossa in 45 patients; the other 45 patients were treated conventionally. RESULTS: Suction drainage was removed between post-operative (p.o.) days 3 and 4. Seroma magnitude and duration were significantly reduced (p 0.004 and 0.02, respectively), and there were fewer evacuative punctures, in patients receiving fibrin glue compared with the conventional treatment group. CONCLUSIONS: Use of fibrin glue does not always prevent seroma formation, but does reduce seroma magnitude, duration and evacuative punctures.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/194091
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 25
  • ???jsp.display-item.citation.isi??? ND
social impact