According to the Italian laws, some categories of workers entrusted with duties possibly constituting a threat to security, physical safety, and health of third parties have to be screened to exclude the use/abuse of the following drugs of abuse: opiates, cocaine, cannabinoids, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, methadone, and buprenorphine. Toxicological tests can be performed with urinary on-site rapid screening devices, provided that sensitivities up to specified cutoffs are ensured. The present study reports performances, in terms of sensitivity, specificity, and accuracy, of an automatic on-site test and of an FPIA-based device, using gas chromatography/mass spectrometry (GC/MS) as a reference methodology. Three levels of concentration were tested, corresponding to the cutoff and to 2 and 3 times the limits, respectively. In terms of sensitivities, neither the onsite nor the benchtop instrumentations gave positive results, since values of zero percentage were obtained for concentrations up to 2-fold the limits. Even if good results were obtained in terms of specificity and accuracy by both devices, none of them seem to be adequate for the current application to the toxicological screening at workplaces. In fact, a rapid screening device can be used for drug tests provided that it ensures sensitivity at the prescribed cutoffs. Data showed that such is completely rejected and a more sensitive instrumentation should be preferred.

Screening of several drugs of abuse in Italian workplace drug testing: performance comparisons of on-site screening tests and a fluorescence polarization immunoassay-based device

MIRAGLIA, Nadia
2011

Abstract

According to the Italian laws, some categories of workers entrusted with duties possibly constituting a threat to security, physical safety, and health of third parties have to be screened to exclude the use/abuse of the following drugs of abuse: opiates, cocaine, cannabinoids, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, methadone, and buprenorphine. Toxicological tests can be performed with urinary on-site rapid screening devices, provided that sensitivities up to specified cutoffs are ensured. The present study reports performances, in terms of sensitivity, specificity, and accuracy, of an automatic on-site test and of an FPIA-based device, using gas chromatography/mass spectrometry (GC/MS) as a reference methodology. Three levels of concentration were tested, corresponding to the cutoff and to 2 and 3 times the limits, respectively. In terms of sensitivities, neither the onsite nor the benchtop instrumentations gave positive results, since values of zero percentage were obtained for concentrations up to 2-fold the limits. Even if good results were obtained in terms of specificity and accuracy by both devices, none of them seem to be adequate for the current application to the toxicological screening at workplaces. In fact, a rapid screening device can be used for drug tests provided that it ensures sensitivity at the prescribed cutoffs. Data showed that such is completely rejected and a more sensitive instrumentation should be preferred.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11591/187747
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 21
social impact